5840-00-003-0339 SPARK GAP Index 6110-00-003-0341 CONTROL,VOLTAGE REGULATOR

National Stock Number:
5985-00-003-0340

Federal Supply Class:
5985

National Item Identification Number:
000030340

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
283670310001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
28367035Z167ASTRO MICROWAVE INC
A1177905584AUTODYNE MANUFACTURING CO INC


Techincal Specification:
STYLE DESIGNATOROFFSET BEND TYPE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLESTRAIGHT SEAM SINGLE TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY8 THREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY
FLANGE STYLECONTACT TYPE ALL FLANGES
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
MATERIALALUMINUM SINGLE TUBING SEGMENT
RUBBER SYNTHETIC SINGLE TUBING JACKET
WAVEGUIDE LENGTH4.062 INCHES NOMINAL
WAVEGUIDE CENTER TO CENTER DISTANCE1.250 INCHES NOMINAL
WAVEGUIDE OUTSIDE WIDTH0.997 INCHES MINIMUM AND
1.003 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.897 INCHES MINIMUM AND
0.903 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.397 INCHES MINIMUM AND
0.403 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.497 INCHES MINIMUM AND
0.503 INCHES MAXIMUM
SURFACE TREATMENTALUMINUM SINGLE TUBING SEGMENT INSIDE SURFACES
CADMIUM SINGLE TUBING SEGMENT OUTSIDE SURFACES
CADMIUM ALL FLANGE OUTSIDE SURFACES
FLANGE INSIDE WIDTH0.897 INCHES MINIMUM AND
0.903 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.397 INCHES MINIMUM AND
0.403 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH2.070 INCHES MINIMUM AND
2.110 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.570 INCHES MINIMUM FIRST FLANGE
1.610 INCHES MAXIMUM SECOND FLANGE
FLANGE DEPTH0.480 INCHES MINIMUM AND
0.520 INCHES MAXIMUM ALL FLANGES
THREAD SERIES DESIGNATORUNC ALL FLANGES SINGLE CONNECTION FACILITY
NOMINAL THREAD SIZE0.164 INCHES ALL FLANGES SINGLE CONNECTION FACILITY
THREAD CLASS2B ALL FLANGES SINGLE CONNECTION FACILITY
THREAD DIRECTIONRIGHT-HAND ALL FLANGES FIRST CONNECTION FACILITY
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
INSERTION LOSS IN DECIBELS0.04
VOLTAGE STANDING WAVE RATIO1.10
PRECIOUS MATERIALSILVER
PRECIOUS MATERIAL AND LOCATIONFLANGE SURFACE SILVER
THE MANUFACTURERS DATA
MANUFACTURERS CODE10001
DESIGN CONTROL REFERENCE2836703